Level Learning
Why EchoPod & Which One?
Learning Notes
The Problem
  • About 1 million small tanks are instrumented each year with contact measurement technology
  • Problem with contact switches is reliability
  • Floats stick, conductance corrodes and pressure fouls resulting in process downtime & maintenance replacement costs
The Solution
  • EchoPod replaces floats, conductance, capacitance and pressure level sensors that fail from contact with sticky, corrosive, dirty, viscous or crystalizing liquids
  • The EchoPod family is offered in 5 models that provide reliable level measurement, switch & control functions for small tanks up to 2.5m
Advantage
  • EchoPod's unique size, packaging and performance characteristics are designed for small tanks
  • NEMA 6P polycarbonate enclosure
  • PVDF transducer and 1" process mount
  • 2" beam width for restrictive spaces and 2" dead band for optimized fill capacity
WebCal
  • WebCal makes measurement, switch & control configuration easy with pre-programmed menus, tank set-point graphics & configuration management tools
  • Available to view or download by clicking here
DL14 & DL24 Sensors - Multi-Function
  • Multi-function sensors that provide 4-20 mA level measurement, relay switch and embedded control functions
  • The DL14 has a range of 2" - 49.2" with a 2" dead band
  • The DL24 has a range of 4" to 98.4" with a 4" dead band
  • Use the DL14 or DL24 when you require measurement, switch and control capabilities in a single product solution
DS14 Sensor - Switch & Control
  • Multi-function sensor that provides relay switch and embedded control functions only
  • The DS14 has no measurement signal output
  • The DS14 has a range of 2" - 49.2" with a 2" dead band
  • Use the DS14 embedded relay control functions to further lower cost by eliminating or reducing the need for external PLC or simple relay control logic hardware
DL10 Sensor - Measurement
  • Single function sensor that provides continuous 4-20 mA level measurement only
  • The DL10 has no relay switch or control functions
  • The DL10 has a range of 2" - 49.2" with a 2" dead band
  • Use the DL10 for small tank process or inventory monitoring applications connected to a PLC
DX10 Sensor - Measurement
  • Single function sensor that provides continuous level measurement with selectable 0-10 voltage or 976 - 2000 Hz frequency signal output only
  • The DX10 has no relay switch or control functions
  • The DX10 has a range of 2" - 49.2" with a 2" dead band
  • Lower cost by eliminating the A-D card or reducing the number of discrete inputs to one


Home | Search | Introduction | About Flowline | What's New | Solutions Wheel | Contact Flowline
Selection Guide | Application Guide | Browse the Products | Request Catalog | New Products
My Distributor | FAQs | Tech-Tips | Case Studies | Flowline News
Glossary | Success Stories | Technical | Chemical
Request Quote | Registration | White Papers

The Flowline Liquid Intelligence and Digital Infinity logo's are all trademarks and/or service marks of Flowline. No trademark or service mark license is granted in connection with the materials contained in the Flowline web site. This web site and all of the information it contains are provided as is without warranty of any kind, whether expressed or implied. All implied warranties, including, without limitation, implied warranties of merchantability, fitness for a particular purpose, and non-infringement, are hereby expressly disclaimed. No reproduction or republication without the prior written permission of Flowline. Specifications subject to change without notice.

©1999-2009 Flowline Liquid Intelligence
10500 Humbolt Street, Los Alamitos, CA 90720 USA
Phone: (562) 598-3015 • Fax: (562) 431-8507 • Email: levelsolutions@flowline.com